LV Aerial Bundled Cable

LV Aerial Bundled Cable

1kV bundle overhead cable system(LOW VOLTAGE AERIAL BUNDLED CABLE) .The main cable is composed of four cables twisted into bundles, and the insulation is XLPE. The electrical and mechanical properties of the bundle line are similar to the overhead insulated line.

LV Aerial Bundled Cable

Get Free Quote

LV ABC (Low Voltage Aerial Bundled Cable) is composed of conductor and insulating layer and twisted into bundles.
The conductor is mainly aluminum or copper, and the copper conductor can be divided into hard copper conductor and soft copper conductor

0.6/1 kv ABC (Aerial Bundled Cables) – NFC 33-209 (Al/XLPE)
0.6/1 kv ABC (Aerial Bundled Cables) – BS 7870-5 (Al/XLPE)
0.6/1 kv ABC (Aerial Bundled Cables) – DES/LVC – ICE 60502 (Al/XLPE)
0.6/1 kv ABC (Aerial Bundled Cables) – ICE 60502 & TNB -(Al/PE)
0.6/1 kv ABC (Aerial Bundled Cables) – HD 626 s1 (Al/XLPE)
0.6/1 kv ABC (Aerial Bundled Cables) – AS/NZS 3560.1 (Al/XLPE)
0.6/1 kv ABC (Aerial Bundled Cables) – ANSI/ICEA S-76-474

ABC Cable All Standard

HD 626

Nominal Cross
Section
Minimum Breaking
Load
Current
Rating in Air
Nominal Ove
all Diameter
Total Weight Outer Diameter
mm² Kn A mm kg/km mm
2x 16 RM 1,910 2,5 72 147 15.6
2x 25 RM 1,200 4,0 107 208 18
2x 35 RM 0,868 5,5 132 277 20
2x 50 RM 0,641 8,0 165 361 23.5
4x 16 RM 1,910 2,5 72 286 18.8
4x 25 RM 1,200 4,0 107 430 21.2
4x 35 RM 0,868 5,5 132 553 24.1
4x 50 RM 0,641 8,0 165 746 27.8
4x 70 RM 0,443 10,7 205 1.009 31.8
4x 95 RM 0,320 13,7 240 1.332 37.8
4x 120 RM 0,253 18,6 290 1.632 54.4
4x 35 + 1x 35 RM 0,868/0,868 5,5/5,5 132/132 694 30
4x 50 + 1x 25 RM 0,641/1,200 8,0/4,0 165/107 814 31.9
4x 50 + 1x 35 RM 0,641/0,868 8,5/5,5 165/132 845 31.9
4x 70 + 1x 25 RM 0,443/1,200 10,7/4,0 205/107 1.105 36
4x 70 + 2x 25 RM 0,443/1,200 10,7/4,0 205/107 1.217 40
4x 70 + 1x 35 RM 0,443/0,868 10,7/5,5 205/132 1.15 36.2
4x 70 + 2x 35 RM 0,443/0,868 10,7/5,5 205/132 1.289 40.1
4x 95 + 1x 25 RM 0,320/1,200 13,7/4,0 240/107 1.438 41.8
4x 95 + 1x 35 RM 0,320/0,868 13,7/5,5 240/132 1.467 41.8
4x 95 + 2x 25 RM 0,320/1,200 13,7/4,0 240/107 1.544 42

AS NZS 3560

Number of cores
x nominal cross section

min. breaking load
of conductor strand

Current rating
in the air
Outer diameter Total weight
mm^2 kN A mm kg/km
2x16 RM 4.4 78 15 140
2x25 RM 7 105 17.6 210
2x35 RM 9.8 125 19.6 270
2x50 RM 11.4 150 22.8 370
2x95 RM 15.3 230 30.6 680
3x25 RM 8.8 97 19 310
3x35 RM 9.8 120 21.1 410
3x50 RM 11.4 140 24.6 550
4x16 RM 8.8 74 18.1 290
4x25 RM 14 97 21.2 410
4x35 RM 19.6 120 23.7 550
4x50 RM 28 140 27.5 740
4x70 RM 39.2 175 31.9 1000
4x95 RM 53.2 215 36.9 1370
4x120 RM 67.2 250 40.6 1690
4x150 RM 84 280 43.9 2020

IEC 60502

Number of cores
x Nominal cross Section
overall diameter weight Maxinum conductor
Resistance
Minimun breaking
Load
current Rating
No.x mm2 mm kg/km Ω/Km KN A
1x16+1x25 RM 15.3 160 1,910 2,5 72
3x16+1x25 RM 19 290 1,200 4,0 107
3x25+1x25 RM 23.2 400 0,868 5,5 132
3x35+1x25 RM 25.6 500 0,641 8,0 165
3x50+1x35 RM 30 680 0,443 10,7 205
3x70+1x50 RM 34.9 920 0,320 13,7 240
3x95+1x70 RM 40.6 1270 0,253 18,6 290
3x120+1x70 RM 44.1 1510 0,206 23,2 334
3x150+1x95 RM 49.2 1870 0,164 28,7 389
3x185+1x120 RM 54.9 2340 0,125 37,2 467
3x25+1x25+1x16 RM 23.2 470 1,910 2,5 72
3x35+1x25+1x16 RM 25.6 560 1,200 4,0 107
3x50+1x35+1x16 RM 30 740 0,868 5,5 132
3x70+1x50+1x16 RM 34.9 980 0,641 8,0 165
3x95+1x70+1x16 RM 40.6 1330 0,443 10,7 205
3x120+1x70+1x16 RM 44.1 1580 0,320 13,7 240
3x150+1x95+1x16 RM 49.2 1940 0,206 23,2 334
3x185+1x120+1x16 RM 54.9 2410 1,910 2,5 72

SANS 1418

Self-supporting

Phase Phase Phase Approx.Ove
all Diameter
Min.Bending
Radius
Max. D.C. Resistance
at 20℃
AAC+UV-XLPE Compact Conductor UV-XLPE Insulation
 Normal Cross
Section of Cores
No.of Al
Wires
Overall
Diameter
Thickness Min. Diameter
No. X mm2 - mm mm mm mm mm kN ohm/km
4 X 16 7 4.8 1.2 0.98 7.2 17.42 2.07 1.91
4 X 25 7 6 1.4 1.16 8.8 21.3 3.3 1.2
4 X 35 7 7 1.6 1.34 10.2 24.68 4.5 0.868
4 X 50 7 8.3 1.6 1.34 11.5 27.83 6.2 0.641
4 X 70 19 10 1.8 1.52 13.6 32.91 8.9 0.443
4 X 95 19 11.6 1.8 1.52 15.2 36.78 12.3 0.32
4 X 120 19 13 1.8 1.52 16.6 40.17 15.6 0.253
4 X 150 19 14.6 1.8 1.52 18.2 44.04 19.2 0.206
3 X 16 7 4.8 1.2 0.98 7.2 15.55 2.07 1.91
3 X 25 7 6 1.4 1.16 8.8 19.01 3.3 1.2
3 X 35 7 7 1.6 1.34 10.2 22.03 4.5 0.868
3 X 50 7 8.3 1.6 1.34 11.5 24.84 6.2 0.641
3 X 70 19 10 1.8 1.52 13.6 29.38 8.9 0.443
3 X 95 19 11.6 1.8 1.52 15.2 32.83 12.3 0.32
3 X 120 19 13 1.8 1.52 16.6 35.86 15.6 0.253
3 X 150 19 14.6 1.8 1.52 18.2 39.31 19.2 0.206
2 X 16 7 4.8 1.2 0.98 7.2 14.4 2.07 1.91
2 X 25 7 6 1.4 1.16 8.8 17.6 3.3 1.2
2 X 35 7 7 1.6 1.34 10.2 20.4 4.5 0.868
2 X 50 7 8.3 1.6 1.34 11.5 23 6.2 0.641
2 X 70 19 10 1.8 1.52 13.6 27.2 8.9 0.443
2 X 95 19 11.6 1.8 1.52 15.2 30.4 12.3 0.32
2 X 120 19 13 1.8 1.52 16.6 33.2 15.6 0.253
2 X 150 19 14.6 1.8 1.52 18.2 36.4 19.2 0.206
1 X 16 7 4.8 1.2 0.98 7.2 7.2 2.07 1.91
1 X 25 7 6 1.4 1.16 8.8 8.8 3.3 1.2
1 X 35 7 7 1.6 1.34 10.2 10.2 4.5 0.868
1 X 50 7 8.3 1.6 1.34 11.5 11.5 6.2 0.641
1 X 70 19 10 1.8 1.52 13.6 13.6 8.9 0.443
1 X 95 19 11.6 1.8 1.52 15.2 15.2 12.3 0.32
1 X 120 19 13.01 1.8 1.52 16.6 16.6 15.6 0.253
1 X 150 19 14.6 1.8 1.52 18.2 18.2 19.2 0.206

Phase + Supporting

Phase Supporting Phase Supporting Approx. Overall
Diameter
AAC+UV-XLPE AAAC+UV-XLPE Compact Conductor UV-XLPE Insulation Conductor UV-XLPE Insulation
Normal Cross Sect
on of Cores
Normal Cross Sect
on of Cores
No.of Al Wires Overall
Diameter
Normal
Thickness
No./Dia.of
Al. Wire
Normal Thickness
No. X mm2 No. X mm2 - mm mm No./mm mm mm
3 X 16 1 X 54.6 7 4.8 1.2 7/3.15 1.6 20.72
3 X 25 1 X 54.6 7 6 1.4 7/3.15 1.6 23.63
3 X 35 1 X 54.6 7 7 1.6 7/3.15 1.6 26.17
3 X 50 1 X 54.6 7 8.3 1.6 7/3.15 1.6 28.53
3 X 70 1 X 54.6 19 10 1.8 7/3.15 1.6 32.34
3 X 95 1 X 54.6 19 11.6 1.8 7/3.15 1.6 35.24
3 X 120 1 X 54.6 19 13 1.8 7/3.15 1.6 37.78
3 X 150 1 X 54.6 19 14.6 1.8 7/3.15 1.6 40.69
3 X 16 1 X 70 7 4.8 1.2 7/3.5 1.6 21.36
3 X 25 1 X 70 7 6 1.4 7/3.5 1.6 24.26
3 X 35 1 X 70 7 7 1.6 7/3.5 1.6 26.8
3 X 50 1 X 70 7 8.3 1.6 7/3.5 1.6 29.16
3 X 70 1 X 70 19 10 1.8 7/3.5 1.6 32.97
3 X 95 1 X 70 19 11.6 1.8 7/3.5 1.6 35.88
3 X 120 1 X 70 19 13 1.8 7/3.5 1.6 38.42
3 X 150 1 X 70 19 14.6 1.8 7/3.5 1.6 41.32

Phase+Supporting+ Service Connection

Phase Supporting Service
Connection
Phase Supporting Service
Connection

Approx.
Overall
Diameter of Bundled Cable

AAC+UV-XLPE AAAC+UV-XLPE AAC+UV-XLPE Compact
Conductor
UV-XLPE Conductor UV-XLPE Compact
Conductor
UV-XLPE AAC+UV-XLPE
Normal Cross Section
of Cores
Normal Cross Section
of Cores
Normal Cross Section
of Cores
No.of
Al.Wire
Overall
Dia.
Normal No./Dia.
of Al. Wire
Normal No. of
Al. Wire
Overall
Dia.
Normal
Thickness Thickness Thickness
No. x mm2 No. x mm2 No. x mm2 - mm mm No./mm mm - mm mm mm
3 X 16 1 X 54.6 1 X 25 7 4.8 1.2 7/3.15 1.6 7 6 1.4 27.05
3 X 25 1 X 54.6 1 X 25 7 6 1.4 7/3.15 1.6 7 6 1.4 30.25
3 X 35 1 X 54.6 1 X 25 7 7 1.6 7/3.15 1.6 7 6 1.4 33.05
3 X 50 1 X 54.6 1 X 25 7 8.3 1.6 7/3.15 1.6 7 6 1.4 35.65
3 X 70 1 X 54.6 1 X 25 19 10 1.8 7/3.15 1.6 7 6 1.4 39.85
3 X 95 1 X 54.6 1 X 25 19 11.6 1.8 7/3.15 1.6 7 6 1.4 43.05
3 X 120 1 X 54.6 1 X 25 19 13 1.8 7/3.15 1.6 7 6 1.4 45.85
3 X 150 1 X 54.6 1 X 25 19 14.6 1.8 7/3.15 1.6 7 6 1.4 49.05
3 X 16 1 X 54.6 2 X 25 7 4.8 1.2 7/3.15 1.6 7 6 1.4 27.05
3 X 25 1 X 54.6 2 X 25 7 6 1.4 7/3.15 1.6 7 6 1.4 30.25
3 X 35 1 X 54.6 2 X 25 7 7 1.6 7/3.15 1.6 7 6 1.4 33.05
3 X 50 1 X 54.6 2 X 25 7 8.3 1.6 7/3.15 1.6 7 6 1.4 35.65
3 X 70 1 X 54.6 2 X 25 19 10 1.8 7/3.15 1.6 7 6 1.4 39.85
3 X 95 1 X 54.6 2 X 25 19 11.6 1.8 7/3.15 1.6 7 6 1.4 43.05
3 X 120 1 X 54.6 2 X 25 19 13 1.8 7/3.15 1.6 7 6 1.4 45.85
3 X 150 1 X 54.6 2 X 25 19 14.6 1.8 7/3.15 1.6 7 6 1.4 49.05
3 X 16 1 X 70 1 X 25 7 4.8 1.2 7/3.15 1.6 7 6 1.4 28.1
3 X 25 1 X 70 1 X 25 7 6 1.4 7/3.15 1.6 7 6 1.4 31.3
3 X 35 1 X 70 1 X 25 7 7 1.6 7/3.15 1.6 7 6 1.4 34.1
3 X 50 1 X 70 1 X 25 7 8.3 1.6 7/3.15 1.6 7 6 1.4 36.7
3 X 70 1 X 70 1 X 25 19 10 1.8 7/3.15 1.6 7 6 1.4 40.9
3 X  95 1 X 70 1 X 25 19 11.6 1.8 7/3.15 1.6 7 6 1.4 44.1
3 X 120 1 X 70 1 X 25 19 13 1.8 7/3.15 1.6 7 6 1.4 46.9
3 X 150 1 X 70 1 X 25 19 14.6 1.8 7/3.15 1.6 7 6 1.4 50.1
3 X 16 1 X 70 2 X 25 7 4.8 1.2 7/3.15 1.6 7 6 1.4 28.1
3 X 25 1 X 70 2 X 25 7 6 1.4 7/3.15 1.6 7 6 1.4 31.3
3 X 35 1 X 70 2 X 25 7 7 1.6 7/3.15 1.6 7 6 1.4 34.1
3 X 50 1 X 70 2 X 25 7 8.3 1.6 7/3.15 1.6 7 6 1.4 36.7
3 X 70 1 X 70 2 X 25 19 10 1.8 7/3.15 1.6 7 6 1.4 40.9
3 X 95 1 X 70 2 X 25 19 11.6 1.8 7/3.15 1.6 7 6 1.4 44.1
3 X 120 1 X 70 2 X 25 19 13 1.8 7/3.15 1.6 7 6 1.4 46.9
3 X 150 1 X 70 2 X 25 19 14.6 1.8 7/3.15 1.6 7 6 1.4 50.1
3 X 16 1 X 54.6 1 X 16 7 4.8 1.2 7/3.15 1.6 7 4.8 1.2 27.05
3 X 25 1 X 54.6 1 X 16 7 6 1.4 7/3.15 1.6 7 4.8 1.2 30.25
3 X 35 1 X 54.6 1 X 16 7 7 1.6 7/3.15 1.6 7 4.8 1.2 33.05
3 X 50 1 X 54.6 1 X 16 7 8.3 1.6 7/3.15 1.6 7 4.8 1.2 35.65
3 X 70 1 X 54.6 1 X 16 19 10 1.8 7/3.15 1.6 7 4.8 1.2 39.85
3 X95 1 X 54.6 1 X 16 19 11.6 1.8 7/3.15 1.6 7 4.8 1.2 43.05
3 X 120 1 X 54.6 1 X 16 19 13 1.8 7/3.15 1.6 7 4.8 1.2 45.85
3 X 150 1 X 54.6 1 X 16 19 14.6 1.8 7/3.15 1.6 7 4.8 1.2 49.05
3 X 16 1 X 54.6 2 X 16 7 4.8 1.2 7/3.15 1.6 7 4.8 1.2 27.05
3 X 25 1 X 54.6 2 X 16 7 6 1.4 7/3.15 1.6 7 4.8 1.2 30.25
3 X 35 1 X 54.6 2 X 16 7 7 1.6 7/3.15 1.6 7 4.8 1.2 33.05
3 X 50 1 X 54.6 2 X 16 7 8.3 1.6 7/3.15 1.6 7 4.8 1.2 35.65
3 X 70 1 X 54.6 2 X 16 19 10 1.8 7/3.15 1.6 7 4.8 1.2 39.85
3 X 95 1 X 54.6 2 X 16 19 11.6 1.8 7/3.15 1.6 7 4.8 1.2 43.05
3 X 120 1 X 54.6 2 X 16 19 13 1.8 7/3.15 1.6 7 4.8 1.2 45.85
3 X 150 1 X 54.6 2 X 16 19 14.6 1.8 7/3.15 1.6 7 4.8 1.2 49.05
3 X 16 1 X 54.6 1 X 16 7 4.8 1.2 7/3.15 1.5 7 4.8 1.2 27.9
3 X 25 1 X 70 1 X 16 7 6 1.4 7/3.15 1.5 7 4.8 1.2 31.1
3 X 35 1 X 70 1 X 16 7 7 1.6 7/3.15 1.5 7 4.8 1.2 33.9
3 X 50 1 X 70 1 X 16 7 8.3 1.6 7/3.15 1.5 7 4.8 1.2 36.5
3 X 70 1 X 70 1 X 16 19 10 1.8 7/3.15 1.5 7 4.8 1.2 40.7
3 X 95 1 X 70 1 X 16 19 11.6 1.8 7/3.15 1.5 7 4.8 1.2 43.9
3 X 120 1 X 70 1 X 16 19 13 1.8 7/3.15 1.5 7 4.8 1.2 46.7
3 X 150 1 X 70 1 X 16 19 14.6 1.8 7/3.15 1.5 7 4.8 1.2 49.9
3 X 16 1 X 70 2 X 16 7 4.8 1.2 7/3.15 1.5 7 4.8 1.2 27.9
3 X 25 1 X 70 2 X 16 7 6 1.4 7/3.15 1.5 7 4.8 1.2 31.1
3 X 35 1 X 70 2 X 16 7 7 1.6 7/3.15 1.5 7 4.8 1.2 33.9
3 X 50 1 X 70 2 X 16 7 8.3 1.6 7/3.15 1.5 7 4.8 1.2 36.5
3 X 70 1 X 70 2 X 16 19 10 1.8 7/3.15 1.5 7 4.8 1.2 40.7
3 X 95 1 X 70 2 X 16 19 11.6 1.8 7/3.15 1.5 7 4.8 1.2 43.9
3 X 120 1 X 70 2 X 16 19 13 1.8 7/3.15 1.5 7 4.8 1.2 46.7
3 X 150 1 X 70 2 X 16 19 14.6 1.8 7/3.15 1.5 7 4.8 1.2 49.9

Cluster mode
3 + 1 or 4 equal sections are used.
3 + 1 is made up of 3 equal section cables and 1 ground cable.

Popular models

1kV LV ABC 3 Core plus Insulated Support plus Auxilarycables
1kV LV ABC 3 Core plus Insulated Supportcables
1kV LV ABC 3 Core plus Insulated Neutral plus Auxilarycables
1kV LV ABC 3 Core plus Insulated Neutralcables
1kV LV ABC 3 Core Bare Supportcables
1kV LV ABC 2 Core plus Insulated Supportcables
1kV LV ABC 2 Core Bare Support plus Auxilarycables
1kV LV ABC 2 Core Bare Supportcables
1kV LV ABC 1 Core plus Insulated Neutralcables
1kV LV ABC 1 Core Bare Supportcables
1kV LV ABC 1 Core

Economic cost analysis

  1. Lv-abc will increase cable cost by 10% compared with common overhead lines.
  2. The cost of the cable is increased.
  3. The cost of fittings and poles will be reduced by 50%.
  4. The labor cost of erection will be reduced by 50%.
  5. Operating costs (such as pruning branches) will be greatly reduced.
  6. Stealing electricity on the line is more difficult.
  7. Safety and reliability will be further improved.

The technology of Low Voltage Aerial Bundled Cable is mature, and its economic benefits are obvious in the long run, especially in the power grid transformation of big cities, because of its small space, its application effectiveness will be more obvious; In the current transformation of rural power grid, the use of cluster cable will bring a series of benefits, such as cost reduction, easy installation and maintenance, anti stealing electricity and so on.

LV Aerial Bundled Cable

LV Aerial Bundled Cable

1kV bundle overhead cable system(LOW VOLTAGE AERIAL BUNDLED CABLE) .The main cable is composed of four cables twisted into bundles, ...
Click For Latest Price
MV Aerial Bundled Cable

MV Aerial Bundled Cable

Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises. We supply ...
Click For Latest Price

Our customers have covered more than 50 countries. Export regions include Europe, North America, North Africa, Middle East, Southeast Asia, etc.HX customer

We certificate by ISO 9001:2015,ISO 14001:2015,OHSAS 18001 ,CCC Certificate ,UL certificate and so on.

ccc certifacte

We provide seaworthy cable packing, wooden drum/wooden-steel drum/ steel drum and etc, cable length can be designed according to customer needs.HX Cable Delivery

We have a complete quality control system, advanced laboratory equipment, to ensure that every batch of goods sent to customers meets the quality requirements. Meanwhile, we accept testing requirements from customers and third-party testing agencies.cable testing

We believe that an excellent professional team is the best guarantee for quality service!

HX Cable personnel

Choose Language